PTS Low-Voltage (LV) Manual Break Switch & Isolators

PTS-WST-8B

Optimised functions for recording items and events

PTS-WST-8B offers a black box record function which can record 5 events circularly, 60 data of 50s before each event record and 10s after each event record. It provides a log function which is capable of recording 200 items circularly.

The microprocessor controller also boasts a 4.3-inch solid colour and 240×128 pixel backlit LCD display and a multilingual interface for English, Simplified Chinese and a variety of other languages.

Collect

  • Voltage, frequency and phase sequence of 2-way 3-phase
  • Active power, reactive power, apparent power, power factor and load current

Display

  • Voltage, frequency and phase sequence of 2-way 3-phase
  • Active power, reactive power, apparent power, power factor and load current
  • Main switch position (working, testing, insulated)
  • Bypass switch position (working, testing, insulated)
  • Independent S1/S2 over current warning or trip alarm functions
  • S1/S2 total kW energy, total Kvar energy
  • S1/S2 main switch and bypass switch accumulated close times
  • Present and past continuous power supply time
  • Total S1/S2 power supply line
Designed for ease of use and installation

Mounting and using a microprocessor controller should be a frictionless experience. Apart from its push-button operation, PTS-WST-8B, offers a modular design, self-extinguishing ABS plastic shell, pluggable terminal, built-in mounting and compact structure for easy installation.

Remote control for enhanced safety

The Dual-RS485 isolated communication interface includes remote controlling, measuring, communication and regulating functions by the ModBus-RTU communication protocol, allowing you to remotely control both the genset and the breaker.

FEATURES
  • Ability to learn synchronous switchover functions, display voltage, frequency and phase differences of 2 circuits
  • Automatically close when the switch PF signal is active for energy-accumulated ATS
  • Over/under voltage and frequency, over current, loss of phase and functions for inverse phase sequence protection
  • Automatic/Manual modes switchover
  • On-site setting of all parameters can be set on-site
  • Password authentication to guarantee staff-only access
  • Genset can be manually-tested on-site to achieve start/stop operation
  • Real-time clock (RTC)
  • Event log function that can record 200 items circularly
  • Black box record function which allows the recording of 5 events circularly, 60 data of 50s before each event record and 10s after each event record
  • Scheduled daily, weekly or monthly functions for gensets, with or without load
  • Ability to control two generators to work in circular, master and balanced running mode.
  • Wide DC power supply range which allows the controller to bear a maximum of 625VAC voltage input
System Type Settings
S1 (Mains) & S2 (Mains) S1 (Mains) & S2 (Generator)
S1 (Generator) & S2 (Mains) S1 (Generator) & S2 (Generator)
Suitable for Various AC Systems
3-phase 4-wires 3-phase 3-wires
Single-phase 2-wires 2-phase 3-wires
IDEAL FOR A WIDE RANGE OF APPLICATIONS
  • Chemical Industry

    CHEMICAL INDUSTRY

  • Data Centres

    DATA CENTRES

  • Healthcare Facilities

    HEALTHCARE FACILITIES

  • Industrial Complexes

    INDUSTRIAL COMPLEXES

  • Mission-Critical Facilities

    MISSION-CRITICAL FACILITIES

  • Refineries

    REFINERIES

  • RETAIL BUSINESS CENTRES

  • Telecom Exchanges

    TELECOM EXCHANGES

  • Waste Water Treatment

    WASTE WATER TREATMENT

Discover the many ways we can help.